    • Operating frequency: 22 kHz
    • Operating Voltage: 9 V
    • Dimensions: 410mm, 85mm, 45mm, 409 g
    • discrimination ferrous metals and other metals
    • Audio, Light and Vibrating Alert
    • Visual and audible low battery warning
    • Sensitivity adjustment to make
    • Rechargeable (Optional)
  • GARRETT CS 5000

    0 out of 5

    Temperatures
    Operating: -4° F (-20° C) to +140° F (60° C)
    Humidity to 95% non condensing
    Storage: -40° F (-40° C) to 158° F (70° C)

    Power
    Fully automatic 100 to 240 VAC, 50 or 60 Hertz, 14 watts; no rewiring,
    switching or adjustments required. Power supply meets UL, CSA, TUV
    and VDE standards.

    Weatherproofing / Foreign Object Protection Standards
    Meets IP 31, IEC Standard. “Degrees of Protection provided by Enclosures,”
    IEC 529.

    Interference Suppression
    100% sensor coil Faraday shielding; special Garrett built-in circuitry
    for noise suppression and ignoring x-ray monitor horizontal sync.

    Traffic Counter
    Built-in and resettable with current reading available on LCD panel.

    Synchronization
    Multiple channels permit several CS 5000s and other Garrett detectors
    to operate simultaneously in close proximity.

    Alarms
    Ready light indicates unit is operational; alarm lights and audible
    alarms are activated when the target amount of metal is detected;
    LED bar graph indicates amplitude of alarm signal.

    Tamper-Proof
    Dual-level access codes required to set or change all sensitivity settings
    and detection programs; one level for use by supervisors in
    selecting programs and sensitivity and the other for initial set-up and
    overall control; non-resettable sequence code logs all changes made
    whenever sensitivity codes are accessed. An audible alarm reports
    unauthorized attempts at access.

    Infrared Sensor
    Improves analysis of detection signal; increases throughput; helps
    eliminate “false alarms” and also provides accurate traffic counter.

    Control Outputs
    Solid state switches (low voltage AC or DC) for operating external
    alarms and control devices.

    Masking
    Programs designed to eliminate the problem of dissimilar targets
    canceling each other.

    Construction
    Attractive scratch and mar-resistant laminate with resilient end caps;
    control panel and cross members made of heavy duty aluminum.

  • Garrett MS 3500

    0 out of 5

    Temperatures
    Operating: -4° F (-20° C) to +140° F (60° C)
    Humidity to 95% non condensing
    Storage: -40° F (-40° C) to 158° F (70° C)

    Power
    Fully automatic 100 to 240 VAC, 50 or 60 Hertz, 14 watts; no rewiring, switching or adjustments required. Power supply meets UL, CSA, TUV and VDE standards.

    Weatherproofing / Foreign Object Protection Standards
    Meets IP 55, IEC Standard. “Degrees of Protection provided by Enclosures,” IEC 529.

    Interference Suppression
    100% sensor coil Faraday shielding; special Garrett built-in circuitry for noise suppression and ignoring x-ray monitor.

    Synchronization
    Multiple channels permit several MS 3500s and other Garrett detectors to operate simultaneously in close proximity.

    Alarms
    Ready light indicates unit is operational; alarm light and audible alarm are activated when the target amount of metal is detected; LED bar graph indicates amplitude of alarm signal.

    Tamper-Proof
    Dual-level access codes required to set or change all sensitivity settings and detection programs; one level for use by supervisors in selecting programs and sensitivity and the other for initial set-up and overall control; non-resettable sequence code logs all changes made whenever sensitivity codes are accessed. An audible alarm reports unauthorized attempts at access.

    Vandal Resistant Construction
    All wiring protected by lockable cabinet. Access control panel may be positioned for easy viewing or locked in cabinet to prevent tampering.

    Construction
    Rugged, heavy duty 3/32″ armor aluminum plates with resilient corner caps for protection against maximum abuse. Construction design provides the unit with maximum installation stability as well as weather tight operation.

    Sequence Log
    A non-resettable counter that indicates the number of attempts to access the MS 3500’s adjustment menu.

    Control Outputs
    Solid state switches (low voltage AC or DC) for operating external alarms and control devices.

    Masking
    Programs designed to eliminate the problem of dissimilar targets canceling each other.

  • Garrett MT 5500

    0 out of 5

    Temperatures
    Operating: -4° F (-20° C) to +122° F (50° C)
    Humidity to 95% non condensing
    Storage: -40° F (-40° C) to 158° F (70° C)

    Power
    Fully automatic 100 to 240 VAC, 50 or 60 Hertz, 24 watts; no rewiring,
    switching or adjustments required.

    Weatherproofing / Foreign Object Protection Standards
    Meets IP 31, IEC Standard. “Degrees of Protection provided by Enclosures,”
    IEC 529.

    Interference Suppression
    100% sensor coil Faraday shielding; RFI interference reduced with
    hardware; special Garrett built-in circuitry for noise suppression and
    ignoring x-ray monitors. Physical interference minimised by coil design
    and circuitry.

    Traffic Counter
    Built-in and resettable with current reading available on LCD panel.

    Synchronisation
    Multiple channels permit several MT 5500s and other Garrett detectors to
    operate simultaneously in close proximity.

    Alarms
    Ready light indicates unit is operational; alarm lights and audible alarms
    are activated when the target amount of metal is detected; location of
    alarm lights on left and right side of display combined with variable tone
    indicates which side of the person the target is located.

    Tamper-Proof
    Dual-level access codes required to set or change all sensitivity settings
    and detection programs; one level for use by supervisors in selecting
    programs and sensitivity and the other for initial set-up and overall control;
    non-re-settable sequence code logs all changes made whenever sensitivity
    codes are accessed. An audible alarm reports unauthorised attempts
    at access.

    Infrared Sensor
    Improves analysis of detection signal; increases throughput; helps
    eliminate “false alarms” and also provides accurate traffic counter.

    Control Outputs
    Solid state switches (low voltage AC or DC) for operating external alarms
    and control devices.

    Masking
    Programs designed to eliminate the problem of dissimilar targets cancelling
    each other.

    Construction
    Attractive scratch and mar-resistant laminate with resilient end caps;
    control panel and cross members made of heavy duty aluminium.

  • GARRETT V Hand-Held Metal Detector

    0 out of 5
    • Three-color LED indication
    • Green LED = ON
    • Amber LED = LOW BATTERY
    • Red LED = ALARM
    • Operating Temperatures -35º F (-37º C) to 158º F (70º C)
    • Width 3.25″ (8.3 cm)
    • Thickness 1.625″ (4.1 cm)
    • Length 16.5″ (42 cm)
    • Total Weight 17.6 oz (500 g)
    • U.S. Trademarks 1,754,933 and 3,236,345
    • Battery Requirements one 9V (included)
  • Inspection concave mirror (S-22)

    0 out of 5

    Inspection concave mirror use under cars with leds

  • Inspection concave mirror (S-42)

    0 out of 5

    Inspection concave mirror use under cars with leds

  • MD300 Handheld metal detector

    MD300 Handheld metal detector

    0 out of 5

    MD300 Handheld metal detector

    • Key features:
      Mini type ,Simple operation
      High sensitivity : can detect the size of pin .
      When metal is detected with the sound ( or vibration ) and light alarm function
      The alkaline battery alarm proportion of 10 % to 15 % of work , can work for 40 hours .
      9V battery the alarm will automatically continuous
      Parameters :
      Power supply
      9V ( can work 40 hours normaly )
      Operating frequency
      20KHz
      Dimension
      L42*W13.8*H11cm
      Alarms
      Light,sound and vibration alarm
      Current job
      50mA
      Power consumption
      220mV
    • Applications : airports , railway stations , docks , prisons , customs , border control and other security departments of security checks; medicine, food , commercial quality inspection system; precious metal detection ( such as gold and silver jewelry factory ) , and other security checks.
      Notes :
      1, When the sensitivity adjustment too high, the boot will be issued after the continuous alarm sound, the sensitivity can be reduced.
      2, Cut off the power after use. Long-term should not remove the battery to prevent overnight, so as not to damage the circuit.
      3, The probe is fixed against a crackling sound when the metal will stop only when the metal continues to sweep audible.
      4.When turned on, the green light to dark and continuous alarm indicates that the voltage is less than has been unable to work , you should replace the battery .
  • MDH-6000

    0 out of 5
    • 6 area
    • sound and light alarm
    • 100degree of sensitivity
    • indicators light on sides to locate warning
    • control voice warning
    • Working outside of the building resistant to Heat,humidity,rain And weather
    • Korean industry by Micro company
  • MDH-6001

    0 out of 5
    • Designed for easy and quick assembly
    • State-of-the-art manufacturing technology
    • LCD display on the control panel
    • Bar-graph indicates the target size
    • Touch pad and 7 segment display helps precise control of program
    • and sensitivity settings.
    • Counting function is included.
    • Compatible with CE regulations for International Standards.
error: Sorry, This Content is Protected!!